LAB GRUPPEN เพาเวอร์แอมป์
FP 10000Q เครื่องขยายเสียง กำลังวัตต์สูง delivers a total of 10000 W

Specifications FP 10000Q
General
Number of channels 4
Peak total output all channels driven 10000 W
Peak output voltage per channel 150 V
Max. output current per channel 38 Arms
Max. Output Power 2 ohms 4 ohms 8 ohms 16 ohms
Per ch. (all ch.’s driven) 2500 W 2100 W 1300 W 660 W
Bridged per ch. - 3) 5000 W 4200 W 2600 W
Performance with Gain: 35 dB and VPL: 150 V
THD 20 Hz - 20 kHz for 1 W <0.1%
THD at 1 kHz and 1 dB below clipping <0.05%
Signal To Noise Ratio >112 dBA
Channel separation (Crosstalk) at 1 kHz >70 dB
Frequency response (1 W into 8 ohms) +0/-3 dB 6.8 Hz - 34 kHz
Input impedance 20 kOhm
Input Common Mode Rejection, CMR 45 dB
Output impedance @ 100 Hz 56 mOhm
Output slew rate into 8 ohms 20 V/microsecond
Voltage Peak Limiter (VPL), max. peak output
VPL, selectable per ch. 150, 121, 101, 83, 70, 56, 47, 38 V
VPL, selectable when bridged 1) 300, 242, 202, 166, 140, 112, 94, 76 V
Voltage Peak Limiter mode (per ch.) Hard / Soft
Gain and Level
Amplifier gain selectable (all channels) 1)
– rear-panel switches
23, 26, 29, 32, 35, 38, 41, 44 dB
Default gain 35 dB
Level adjustment (per ch.) Front-panel potentiometer, 21 position detented from -inf to 0 dB
Connectors and Switches
Input connectors (per ch.) 3-pin XLR, electronically balanced
Output connectors (per ch.) Neutrik Speakon or Binding Posts (must be specified upon order)
Output bridge mode A+B, C+D - Ch.’s A and C are signal input source
NomadLink® network On board, 2 x RJ45 EtherCon connectors, IN and OUT
Intelligent fans (on/off) Yes, depending on presence of output signal
Power on/off and Remote enable on/off Individual switches on front-panel
Cooling Two fans, front-to-rear airflow, temperature controlled speed
Front-panel indicators:
Common NomadLink® Network; Power Average Limiter (PAL) 2); Power on
Per channel Signal present / High-impedance; -20 dB, -15 dB, -10 dB and -4 dB output signal;
Voltage Peak Limiter (VPL); Current Peak Limiter (CPL): Very High Frequency (VHF); High temperature; Fault; Mute
Power
Operating voltage, 230 V / 115 V nominal 4) 130-265 V / 65-135 V
Minimum power-up voltage, 230 V / 115 V 171 V / 85 V
Power Average Limiter (PAL) 2) Yes
Soft start / Inrush Current Draw Yes / max. 5 A
Mains connector 230 V CE: 16 A, CEE7; 115 V ETL: 30 A Twist lock
Dimensions (W/H/D) W: 483 mm (19”), H: 88 mm (2 U), Overall D: 396 mm (15.6”), Mounting D: 358 mm (14.1”)
Weight 12 kg (26.4 lbs.)
Finish Black painted steel chassis with black painted steel / aluminum front
Approvals CE, ANSI/UL 60065 (ETL), CSA C22.2 NO. 60065, FCC